ROHDE & SCHWARZ FSIG13 CALIBRATION and ROHDE & SCHWARZ FSIG13 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ROHDE & SCHWARZ FSIG13 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Analyzer?
Shop for Comparable Products on our
 used Signal Analyzer page

 
   ROHDE & SCHWARZ FSIG13 (1119.6001.73)   Description / Specification:    
ROHDE & SCHWARZ FSIG13 13 GHz Signal Analyzer

The Rohde & Schwarz FSIG13 (1119.6001.73) 13 GHz Signal Analyzer provides in a single unit comprehensive and easy-to-use measurement functions in the, frequency domain, time domain, modulation domain and code domain (cdmaOne forward channel). In the frequency domain, the FSIG 13 measures intermodulation and harmonics with great accuracy. The high 3rd-order intercept point in conjunction with the extremely low noise floor yields a wide intermodulation-free dynamic range and ensures reliable performance of even sophisticated measurements like spurious measurements. The maximum input frequency of 13 GHz allows even out-of-band spurious measurements. In the time domain, the FSIG 13 features all modern capabilities of burst analysis in TDMA systems; gate functions, trigger delay and integrated RF trigger in conjunction with a short sweep time of 1 µs ensure precise measurement of the timing characteristics of mobile radio systems. In the modulation domain, the integrated vector signal analyzer provides diverse measurements on GSM, EDGE, IS-136, cdmaOne, W-CDMA/ 3GPP signals. These convenient presettings make it superfluous for the user to spend valuable time in looking up specifications and go towards enhancing the measurement reliability. An optional application firmware FSIQ-K71allows power measurement in the 64 Walsh code channels of a cdmaOne signal (forward channel). The results can be output numerically or displayed as a bargraph. Features. Frequency range: 9 kHz to 13 GHz. Resolution bandwidth: 1 kHz to 10 MHz in 1/2/3/5 steps. 5-pole resolution filters with high selectivity. Displayed average noise floor typically -130 dBm in 1 kHz bandwidth. Third-order intercept +22 dBm. Phase noise -150 dBc(1 Hz) at 5 MHz offset. 75 dB ACPR dynamic range for W-CDMA (4.096 MHz integration BW). Total level uncertainty: <1 dB up to 2.2 GHz, <1.5 dB up to 7 GHz. RMS detector for high-precision power measurements irrespective of waveform. Fast time domain analysis with 1 µs zero span sweep time. Integrated broadband vector signal analyzer for GSM, EDGE, IS-136, cdmaOne, W-CDMA and 3GPP signals with versatile result display: I and Q signal, magnitude and phase, vector and constellation diagrams, tabular output with numerical values of modulation errors and demodulated bit sequence. Display: 24 cm colour diplay TFT (9.5"). Options Hardware. FSE-B13, 1-dB attenuator. FSE-B16, Ethernet Interface. FSE-B17, 2nd IEC/IEEE Bus Interface. FSE-B22, Increased level accuracy up to 2 GHz. FSIQ-B70, DSP and IQ memory extension 2x 512 k. Options Software. FSE-K10, GSM Application Firmware, Mobile. FSE-K11, GSM Application Firmware, BTS. FSIQ-K71, IS-95 Application Firmware, BTS (requires FSIQ-B70).



 

Standard Calibration $665.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ROHDE & SCHWARZ FSIG13. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your ROHDE & SCHWARZ FSIG13 CALIBRATION and/or ROHDE & SCHWARZ FSIG13 13 GHz Signal Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: